Analytical Balance-120/250gm (5 Digit)
Read moreSpecification: Maximum capacity [Max] 120 / 250 g Minimum load 1 mg Readability [d] 0.01 / 0.1 mg Tare range -250 g Standard Repeatability [5% Max] 0.006 mg Standard Repeatability [Max] 0.06mg Permissible Repeatability [5% Max] 0.012mg Permissible Repeatability [Max] …
-
Analytical Balance -210gm (5 Digit)
Read moreSpecification: Maximum capacity [Max] 210 g Minimum load 1 mg Readability [d] 0.01 mg Tare range -210 g Standard Repeatability [5% Max] 0.006 mg Standard Repeatability [Max] 0.025 mg Standard minimum weight (USP) 12 mg Standard minimum weight (U=1%, k=2) …
-
Micro Balance-6.1gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 6.1 g Minimum load 0.1mg Readability [d] 1µg Tare range -6.1g Standard Repeatability [5% Max] 0.8µg Standard Repeatability [Max] 2.5µg Permissible Eepeatability [5% Max] 1.5µg Permissible Repeatability [Max] 3µg Standard minimum weight (USP) 1.6mg Standard minimum …
-
Micro Balance-52gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 52g Minimum load 0.5mg Readability [d] 5µg Tare range -52g Standard repeatability [5% Max] 2.2µg Standard repeatability [Max] 6µg Standard minimum weight (USP) 4.4mg Standard minimum weight (U=1%, k=2) 0.44mg Permissible repeatability [5% Max] 3.4µg Permissible …
-
Micro Balance-53gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 53g Minimum load 0.5mg Readability [d] 1 µg Tare range -53g Standard Repeatability [5% Max] 1.5µg Standard Repeatability [Max] 6µg Permissible Repeatability [5% Max]2.4µg Permissible Repeatability [Max] 8µg Standard minimum weight (USP) 3mg Standard minimum weight …
-
Micro Balance-6/21gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 6 / 21g Minimum load 0.1mg Readability [d] 1 / 2µg Tare range -21g Standard Repeatability [5% Max] 1.3µg Standard Repeatability [Max] 3.5µg Permissible Repeatability [5% Max] 2µg Permissible Eepeatability [Max] 5µg Standard minimum weight (USP) …
-
Micro Balance-21/52gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 21 / 52g Minimum load 0.1mg Readability [d] 1 / 5 µg Tare range -52g Standard Repeatability [5% Max] 1.5µg Standard Repeatability [Max] 6µg Permissible Repeatability [5% Max] 2.4µg Permissible Repeatability [Max] 8µg Standard minimum weight …
-
Micro Balance-21gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 21g Minimum load0.1mg Readability [d] 1µg Tare range-21g Standard Repeatability [5% Max] 1.3µg Standard Repeatability [Max] 3.5µg Permissible Repeatability [5% Max]2µg Permissible Repeatability [Max] 5µg Standard minimum weight (USP) 2.6mg Standard minimum weight (U=1%, k=2)0.26mg Linearity±9µg …
-
Micro Balance-52gm (6 Digit)
Read moreSpecification: Maximum capacity [Max] 52g Minimum load 0.5mg Readability [d] 5µg Tare range-52 g Standard Repeatability [5% Max] 2.2µg Standard Repeatability [Max] 6µg Permissible Repeatability [5% Max] 3.4µg Permissible Repeatability [Max] 8µg Standard minimum weight (USP) 4.4mg Standard minimum weight …
-
Analytical Balance-110gm (5 Digit)
Read moreSpecification: Maximum capacity [Max] 110g Minimum load 1mg Readability [d] 0.01mg Tare range -110mg Linearity ±0.06mg Eccentric load deviation 0.06mg Stabilization time 5 s (30 s for filters) Standard Repeatability [5% Max] 0.007 Standard Repeatability [Max] 0.02 Permissible Repeatability [5% …
-
Analytical Balance-50gm (5 Digit)
Read moreSpecification Maximum capacity [Max] 52g Minimum load 1mg Readability [d] 0.01mg Linearity ±0.03mg Eccentric load deviation 0.03 mg Tare range -52 mg Stabilization time 5 s (30 s for filters) Standard Repeatability [5% Max] 0.007 mg Standard Repeatability [Max] 0.01mg …
-
Analytical Balance-220gm
Read moreInspection: Maximum capacity [Max] 220g Minimum load 10mg Readability [d] 0.1 mg Linearity±0.2mg Stabilization time2 s Tare range -220g Standard Repeatability [5% Max] 0.07 mg Standard Repeatability [Max] 0.08mg Standard minimum weight (USP) 140mg Standard minimum weight (U=1%, k=2) 14mg …
-
Moisture Analyzer-110gm
Read moreSpecification Maximum capacity [Max] 110 g Readability [d] 1 mg Moisture content readability 0.001% Tare range-110 g Adjustment external Display LCD (backlit) Drying temperature range max 250°C Drying method 4 drying profiles (standard, fast, step, mild) Communication interface RS232, USB-A, …
-
Muffle Furnace (1300˚C)
Read moreStandard Equipment: Temp. max 1300 °C Heating from two sides Heating elements on support tubes ensure free heat radiation and a long service life Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber Dual shell housing made of textured …
-
Muffle Furnace (1100˚C)
Read moreStandard Equipment: Temp. max 1100 °C Heating from two sides from heating elements protected in quartz glass tubes Fast heating times (see table) Maintenance-friendly replacement of heating elements and insulation Housing coated in RAL Solid state relays provide for lownoise operation …
-
PCR & Thermocycler
Read moreKey Features • Intuitive 7” colour LCD touch screen for real time monitoring of experimental temperature and easy operation with both chinese and english version interface • Six high-performance Peltier structures for temperature control accuracy. • Touchdown PCR and long …